<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-10 19-35-23
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
103.10 MHz 5/5, 57 dBuV RMC
Pilot RDS Phase Difference
0.0 kHz 3.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
3 kHz 74 kHz 9553 0,1151
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
5,6 dBr 7,56 dBr 8,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RMC " F216 0 (No PTY) 1 0 1 1 19:35, 10.02.2025
RT
-
AF EON
87.6, 87.7, 90.2, 90.4, 90.6, 92.3, 95.3, 96.4, 97.3, 99.1, 100.7, 101.2, 101.6, 102.6, 103.1, 103.2, 103.3, 103.6, 104.1, 104.8, 106.7, 107.2, 107.3, 107.5, 107.9 MHz -
FM Scope Station: 103.10 MHz, signal: 5/5 (57 dBuV) Max at: 74 kHz MIN: 3 kHz % above 75 kHz: 0,1151 Acquired: 2025/02/10 19:34:20 Total samples: 9553 Equivalent time: 0:07:57 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,5 dBr MIN: 5,6 dBr AVE: 7,56 dBr % above 10,0 dBr: 0,0 Last value: 5,6 dBr (2025/02/10 19:34:19) Station: 103.10 MHz, signal: 5/5 (57 dBuV) 19:27 19:28 19:29 19:30 19:31 19:32 19:33 19:34 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality